Resources / Product evolution

Release notes

The evolution of PVLTRA, from terrain to editable design. Explore released improvements by version and technical area.

Latest version

3.0.11

Released

More control over grading and pile extensions

Released

3.0.11

More control over grading and pile extensions

This release improves the search for design terrain near site boundaries, the comparison of earthworks alternatives and the readability of cut-and-fill results. It also clarifies remaining pile-extension allowances and correction results in AutoCAD and ZWCAD.

Earthworks

  • Transition near site boundaries

    When terrain near the boundary prevents the first tracker row from meeting the checks, the tool can search again for a continuous design surface in that sector and adjust how structures rest on it, without extending the boundary or relaxing project limits.

  • More alternatives in Balanced mode

    Solutions that already pass the design checks are compared by cut-and-fill volumes. If the search is still reducing earthworks appreciably, it can continue rather than stopping at the first valid alternative. An absolute minimum is not guaranteed.

  • Clearer volume map and civil report

    The 2D map distinguishes elevation changes of up to 50 mm, which remain included in the volume calculation. The report identifies structures that need review and, when evidence is available, states which check prevented the surface from being verified.

Pile analysis and correction

  • Cumulative extension allowance

    The remaining allowance accounts for extensions already applied to each pile. Raising a whole structure uses the smallest allowance among its piles; individual correction checks each pile separately.

  • Rebuilt articulated trackers

    The analysis recognizes the pile group associated with a rebuilt articulated tracker. If no valid association is found, it reports the omitted elements instead of assigning them to another group.

  • Separated 2D results

    The report separates piles that can be or have been corrected from cases still pending, showing the previous extension, the amount applied in this step and the reason when correction is incomplete.

Released

3.0.10

Layout by inverter groups and clearer tools

This release extends the placement of complete inverter-and-structure groups, refreshes the forms in the reviewed tools, and makes height and 3D collision analyses easier to read in AutoCAD and ZWCAD.

Solar layout

  • Complete groups from a drawing model

    Place an inverter and its associated structures from a selection in the drawing. You can reproduce the arrangement exactly or adapt it to the layout using configured guides, sectors and clearances, including across multiple site boundaries.

  • Controlled replacement

    The tool respects physical corridors and creates only complete groups. When replacing a previously identified layout, it protects the model group and elements outside the selected scope.

  • Associations retained

    The relationship between each inverter and its structures is saved for the next electrical assignment step. This association does not replace capacity or electrical parameter checks.

User experience

  • Refreshed forms

    The reviewed tools share a more consistent presentation, with settings grouped by task, accessible actions, and libraries and supporting editors aligned with the main form.

  • Help and readability

    Visual help and manuals are updated in the project language. The reviewed forms adapt better to different display scales and text sizes, with alignment, clipping and repaint issues corrected.

Structure analysis

  • Clearer configuration

    Tracker wind-exposure and adjacent-structure height analyses have reorganized forms, clearer options and colors, and better-aligned controls.

  • Height labels without overlap

    dZ labels adjust their size or position when they overlap other labels from the same analysis, without hiding measurements or changing calculations. Rerun the analysis to update labels already drawn.

Ground clearance and 3D collisions

  • New configuration window

    Set the critical threshold in project units and choose colors for pass, warning and critical states in a form instead of entering options at the command line.

  • Choose your outputs

    Choose independently whether to color structures, draw connectors and markers, or create the legend. The previous calculation rules are preserved.

  • Before running the analysis again

    A new run clears previous connectors and legends from their layers. Review results in other areas before repeating the operation.

Released

3.0.9

More control over trackers, layout and CAD workflows

This release adds sector guides along roads, physical gaps at pile-supported tracker joints and more consistent 3D terrain adaptation. It also improves boundary selection in Auto-Route.

Tracker design

  • Physical gaps above piles

    Manual joints can include a configurable gap directly above a pile. Changing its width recalculates spans and supports together, keeping the joint and pile aligned.

  • Consistent settings and geometry

    The module layout and resulting length match the preview and 2D and 3D blocks. Recalculated widths and positions are retained when the structure is reopened or rebuilt.

Terrain adaptation

  • Continuity between spans

    When articulated trackers are adapted to terrain, spans stay connected and joints remain above their piles. Developed length and module geometry are preserved.

  • Piles retained in the catalog

    Piles in the original structure definition remain available when generating further 3D structures.

Layout along roads

  • Sector guides

    Structure ends can follow a road without rotating the structures or changing pitch. The same guide can be used on both sides of a road, or different guides can be assigned by area.

  • Configurable clearance and scope

    Minimum clearance uses project units and the settings remain linked to the site boundary. Guides must be open polylines with straight segments; mechanically coupled twin-row trackers are not supported in this mode.

Routing and CAD interaction

  • Copy boundary settings without losing focus

    When choosing a boundary in Auto-Route, selection stays in the CAD drawing and the form returns after confirmation or cancellation.

  • Current settings preserved

    Cancelling or selecting a boundary without a valid profile does not replace the current form settings. Routing rules and measurements are unchanged.

Released

3.0.8

A stronger foundation for everyday work

PVLTRA 3.0.8 brings general improvements to efficiency, security and usability in CAD-based design workflows.

Efficiency and security

  • Operational efficiency

    Internal refinements aimed at reducing friction in day-to-day PVLTRA use and supporting continuity in technical work.

  • Application security

    This release includes general security improvements as part of the product’s ongoing development and maintenance.

User experience

  • Clearer interactions

    Usability refinements aim to make work clearer and more consistent across PVLTRA tools.

Released

3.0.7

More precise surface flow, piling and electrical deliverables

Improvements to terrain analysis, piling reports, structure editing and cable schedules for AutoCAD and ZWCAD.

Surface flow analysis

  • Original or final terrain

    The analysis can use the original TIN or, when available, the final earthworks terrain. Regular sampling preserves the terrain elevations without smoothing them.

  • Clearer results on dense terrain

    Grouped meshes reduce rendering load, while more arrows appear where flow accumulation is higher. The user’s selected language and visual style are preserved.

  • ZWCAD arrows and nearly closed boundaries

    Arrow creation is corrected in ZWCAD, and site boundaries with almost coincident endpoints can be analyzed without modifying their original geometry.

Piling report

  • Grouped order quantities

    The fixed-structure report groups pile quantities by order length and status instead of listing every pile as a separate line.

  • Traceable ground-clearance checks

    Frames with insufficient clearance are flagged, and the geometric references used for the calculation are shown. The default minimum is 500 mm and can be edited.

  • Editable tolerance

    The default under-driving tolerance is now 15 mm. Values already saved in a drawing are respected rather than overwritten.

Structure editing

  • Update structures without losing data

    Updating fixed structures or trackers preserves 2D and 3D instances, TAGs and custom attributes. Changing module power updates structure power without erasing associated data.

  • Safer consecutive edits

    A structure can be edited again from the same window, and an update cannot overwrite another family that already uses the resulting name.

Automatic routing and reports

  • More accurate cable grouping

    Identified terminal approaches to inverters and transformer stations no longer distort schedule groupings. Complete strings remain together, without changing cable routes or individual measurements.

  • Excel and site-boundary summaries

    The schedule distinguishes shared DC conduits, strings in the cable’s own conduit and AC circuits. Origin and destination references and totals by site boundary are corrected. In the trench editor, non-editable cells are shaded grey.

  • 2D drawings saved when you choose

    Each 2D report opens as a new drawing for manual saving. Earlier schedules and reports must be regenerated to reflect these corrections.

Released

3.0.6

More control over electrical assignments and trench design

Capacity is visible during manual assignment, while Auto-Route separates rows and inverters when distributing DC cables across conduits.

Electrical assignment

  • Capacity visible before confirmation

    Inverter-to-station assignment shows the forecast transformer load in kVA, while structure-to-inverter assignment shows occupancy in strings as equipment and structures are selected. Over-capacity assignments are clearly flagged without being blocked.

  • Additive structure reassignment

    Structure-to-inverter assignment adds selected structures to the existing group without removing those already assigned to the inverter. It keeps the destination TAGs and colors and reorganizes affected source groups.

  • Coordinated tables and connections

    When summaries are updated, tables highlight overloads and linked connections and labels are synchronized. Updating the tables remains optional.

Auto-Route and trenches

  • DC conduits by row and inverter

    Automatic cable routing groups cables from aligned structures by physical row, inverter and site boundary. Cables from different rows or inverters do not share a conduit merely because they use the same trench.

  • Configurable capacity per conduit

    Each trench type has a maximum number of DC cables per conduit, separate from the trench-wide limit. When several conduits are needed, cables are distributed evenly without splitting a string.

  • Reports showing actual occupancy

    Excel and 2D reports show the number of conduits, the highest actual cable count per conduit and the trench total. Earlier reports must be regenerated to reflect the new rule.

Released

3.0.5

More precise terrain, broader CAD compatibility and electrical control

This release improves triangulation, the AutoCAD and ZWCAD experience, and the preparation of electrical networks and deliverables inside CAD.

Topography and terrain

  • Arcs and elevations in triangulation

    Terrain generation now reads 2D polyline arcs and elevations correctly in Standard and Deep, avoiding misplaced points and elevations that could distort the mesh. Previously affected meshes must be regenerated.

Interface and CAD compatibility

  • Forms that adapt to screen scaling

    Fields, lists, tabs and close buttons are clearer at different display scales in AutoCAD and ZWCAD, without changing calculations or project data.

  • Ribbon in AutoCAD 2027

    Icon loading is adapted to the .NET 10 environment so the PVLTRA tab starts correctly in AutoCAD 2027 while remaining compatible with earlier versions.

  • Pile and slope form images

    Pile analysis and structure-slope forms load their graphics without relying on serialization disabled in Civil 3D 2027.

Electrical design and trenches

  • Tables linked to their site boundary

    Summary tables are identified by their link to the site boundary rather than their position in the drawing. They can be updated after being moved without affecting another plant’s tables.

  • Editable automatic trenching

    Automatic routing creates editable polylines from the layout and electrical assignments. Existing trenches can be reused or replaced, and remain intact if the operation is not applied.

  • Collectors and road crossings

    The design favors shared connections, continuous corridor axes and straighter road crossings while respecting geometric and electrical constraints.

  • Auto-Route by site boundary

    Custom trench types are retained per area. Excel reports and 2D drawings are generated separately for each boundary, and valid existing secondary trenches are reused.

Updates

  • Direct access to release notes

    The message confirming that PVLTRA is up to date includes a link to these release notes in the project language.

Released

3.0.4

More control across terrain, structures and deliverables

This update connects 3D modeling, topography, civil analysis and technical outputs more closely inside CAD.

Layout and design

  • 3D model without a terrain TIN

    The model can use a flat reference when no usable TIN is available yet, while preserving structure and equipment heights.

  • Articulated trackers

    Individual joint limits and manually placed joints remain available when the 3D model is rebuilt.

  • Clearer structure editing

    The design shows full dimensions and warns before creating block identifiers with incompatible characters.

Terrain and civil analysis

  • More precise grading diagnostics

    Reports distinguish geometry, slope and articulation issues while keeping civil and structural checks in place.

  • Faster tracker profiles

    The calculation reuses exact checks where a span does not cross a joint, without changing feasibility criteria.

Mapping and site boundaries

  • Persistent spatial reference

    New site boundaries keep their geographic data and reuse it when moving between the CAD drawing and map.

  • Recoverable original geometry

    When a replacement boundary or terrain is generated, the original outline remains on a layer that can be shown again.

Electrical design

  • Independent work by site boundary

    Auto-Route stores each area’s settings and creates its tables, Excel files and 2D drawings separately.

  • Better cable routing warnings

    Unnecessary distance warnings are avoided when a cable follows adjacent structures to a trench; genuinely unsupported routes are still flagged.

Piles and equipment

  • Clearer pile correction

    Custom extension sizes can be set, and the 2D analysis separates correctable piles from those needing review.

  • Valid block names

    Inverter and transformer forms warn when an identifier contains incompatible characters.

Export

  • PVsyst across multiple site boundaries

    A single operation can include selected areas and relevant nearby obstacles, without adding objects outside the scope.

Released

3.0.3

More precise layouts and smoother calculations

Improvements for iterating on large plants, understanding civil results and preparing consistent CAD outputs.

Solar layout

  • Alignment by sector

    Areas separated by roads or discontinuities can be optimized independently while preserving alignment within each sector.

  • Geometry and constraints

    Placement, structure compaction, site boundaries and obstacles are handled more consistently.

Global grading

  • More efficient repeated calculations

    The analysis reuses valid work within a CAD session and explains more clearly why a surface cannot be approved.

  • Configurable topsoil

    Topsoil thickness can be set in the form and included in the report without changing the design terrain.

Equipment and exports

  • Inverters in large projects

    Placement avoids repeated calculations and accepts nearly closed boundaries without changing the drawing geometry.

  • TIN selection on export

    Point export can use either the original terrain or the terrain generated through leveling when both are present.

Released

3.0.2

Clearer electrical design and documentation

An update focused on electrical assignment, routing and easier access to results in extensive projects.

Performance

  • Faster site-boundary tables

    Shared analysis is reused to speed up summaries in dense drawings while preserving results and units.

Electrical design

  • Assignment by site boundary

    Structures are grouped more evenly and closer to their inverters while preserving approved manual assignments.

  • Inverter repositioning

    Pile positions, roads, distances and collisions are considered before finalizing placement.

  • Manual and automatic routing

    Manual routing uses the same settings as Auto-Route, which now offers greater control over trenches and reports.

Documentation

  • Renewed manuals

    Spanish and English help includes screenshots, parameters, expected results and navigation organized by module.